LW36-126T-(W)3150-40

LW36-126T (W)/3150-40 Outdoor High Voltage SF6 Dead Tank Circuit Breaker

The LW36-126T (W)/3150-40 Outdoor High Voltage SF6 Dead Tank Circuit Breaker is a reliable transmission-class circuit breaker developed for 72.5kV and 126kV, 50Hz three-phase AC power systems. It combines advanced SF6 switching technology with a compact dead tank structure, providing dependable circuit interruption, protection, and control performance for high-voltage substations and transmission networks.

Get a Quote

Overview


The LW36-126T (W)/3150-40 Outdoor High Voltage SF₆ Dead Tank Circuit Breaker is a reliable transmission-class circuit breaker developed for 72.5kV and 126kV, 50Hz three-phase AC power systems. By integrating the circuit breaker and current transformer (CT) into a compact dead tank design, it provides dependable switching, protection, and control performance for substations and high-voltage transmission networks.

The interrupter chamber is horizontally installed inside a grounded aluminum alloy enclosure and driven by the CT26 spring operating mechanism. With SF₆ gas serving as both the insulation and arc-extinguishing medium, the circuit breaker delivers excellent dielectric performance, strong short-circuit interruption capability, and extended electrical service life.

Through CNC precision manufacturing and the use of high-quality bearings from internationally recognized suppliers, including IKO, INA, and SKF, the LW36-126T ensures outstanding mechanical stability and operational reliability, with a mechanical endurance of up to 10,000 operations.

The LW36-126T SF₆ Dead Tank Circuit Breaker is widely applied as a transmission line breaker, transformer feeder breaker, bus coupler breaker, and capacitor bank switching breaker in utility substations, power transmission systems, and high-voltage grid applications.

 

Model and meaning


LW36-126T-(W)3150-40-model

 

Features


Integrated Dead Tank Structure

The LW36-126T Outdoor SF₆ Dead Tank Circuit Breaker features a compact dead tank design, with the interrupter chamber installed inside a grounded aluminum alloy enclosure. The integrated current transformer (CT) design eliminates the requirement for external CT installation, helping reduce equipment footprint, simplify primary circuit connections, and optimize overall substation construction costs.

Key advantages include:

  • Integrated circuit breaker and CT configuration
  • Compact equipment layout
  • Enhanced operational safety
  • Simplified substation design
  • Reduced installation complexity and project time

Advanced SF6 Arc-Extinguishing Technology

The LW36-126T uses SF6 gas as both the insulation and arc-quenching medium, ensuring reliable switching performance in high-voltage transmission applications.

Main features include:

  • Excellent dielectric insulation capability
  • High short-circuit current interruption performance
  • No restrike during capacitive current switching
  • Extended electrical endurance
  • Stable operation under demanding fault conditions

The optimized interrupter design and advanced arc-control technology improve switching efficiency while minimizing operating energy requirements.


High Mechanical Reliability

The major mechanical components of the LW36-126T are manufactured through precision CNC machining processes to ensure high accuracy and consistent quality.

Equipped with premium bearings from internationally recognized brands such as IKO, INA, and SKF, the breaker provides:

  • Smooth mechanical operation
  • Reduced transmission friction
  • Reliable synchronization performance
  • Long-term mechanical stability
  • Mechanical endurance of up to 10,000 operations

Excellent Outdoor Corrosion Protection

Designed for continuous outdoor operation, the LW36-126T incorporates multiple corrosion-resistant protection measures, including:

  • Stainless steel operating mechanism cabinet
  • Hot-dip galvanized structural components
  • Hot-dip galvanized fastening parts
  • High-strength support structure
  • Strong resistance against humidity, salt spray, and industrial contaminants

The anti-pollution (W) version is especially suitable for coastal areas and industrial environments with high pollution levels.


Superior Current Carrying Performance

The LW36-126T successfully completes temperature rise tests at 120% of rated current (3,780A), providing sufficient thermal margin for long-term continuous operation.

Additional benefits include:

  • Low temperature rise characteristics
  • Stable contact resistance
  • Excellent overload capability
  • Reliable continuous current transmission performance

Simplified Installation and Low Maintenance

The compact structure of the LW36-126T simplifies transportation, installation, commissioning, and routine maintenance processes.

Additional features include:

  • Centralized CT26 spring operating mechanism
  • Online SF₆ gas density monitoring system
  • Fast motor charging time (≤15 seconds)
  • Reduced maintenance requirements
  • Extended inspection intervals

 

Technical Data


Electrical Ratings

 

Item Unit Parameter
Rated Voltage kV 126
Rated Current A 3150
Rated Frequence Hz 50
Rated Short-Circuit Breaking Current kA 40
Rated Short-Circuit Making Current (Peak) 100
Rated Peak Withstand Current 100
Rated 4s Short-Time Withstand Current 40
First-Pole-to-Clear Factor / 1.5
Rated operating sequence / O–0.3s–CO–180s–CO
Out-of-Phase Breaking Current kA 10
Line Charging Switching Current A 31.5
Mechanical Life Times 10000
Radio Interference Voltage μV ≤500

 

Insulation Performance

Item Specification
Power Frequency Withstand Voltage (to Ground) K × 230kV
Power Frequency Withstand Voltage (Across Open Contacts) K × 265kV
Lightning Impulse Withstand Voltage (to Ground) K × 550kV
Lightning Impulse Withstand Voltage (Across Open Contacts) K × 630kV
Power Frequency Withstand Voltage at Zero SF6 Pressure(5min) K × 95kV
Creepage Distance 3906mm / 3150mm
Altitude Correction Factor
Installation Altitude K Factor
2000m 1.13
3000m 1.28

 

Mechanical Performance

Item Specification
Pole Spacing 1750 mm
Contact Stroke 120 ±3 mm
Contact Travel 25 ±2 mm
Opening Speed 4.2–5.0 m/s
Closing Speed 2.2–3.0 m/s
Opening Time ≤40 ms
Closing Time ≤100 ms
Total Breaking Time ≤60 ms
CO Time ≤80 ms
O-CO Interval 300 ms
Three-Phase Opening Synchronization ≤2 ms
Three-Phase Closing Synchronization ≤3 ms

 

CT26 Spring Operating Mechanism

Item Specification
Auxiliary Voltage DC110V / DC220V
Closing & Trip Coil Voltage DC110V / DC220V
Energy Storage Motor AC110V / AC220V / DC110V / DC220V
Motor Operating Voltage 85–110% Rated Voltage
Motor Power 600W
Charging Time ≤15s
Heater Voltage AC220V
Auxiliary Switch Voltage AC220V / DC220V
Auxiliary Switch Current 10 A
Auxiliary Contacts 10 NO + 10 NC

 

SF6 Gas Characteristics

Item Specification
Rated Gas Pressure (20°C) 0.5 MPa
Alarm Pressure 0.45 ±0.03 MPa
Annual Leakage Rate <0.5%
Moisture Content ≤150 × 10⁻⁶ (V/V)
SF₆ Gas Weight 15 kg

 

Dimensions & Installation

Item Specification
Total Weight 2200kg
Wind Load Area 4.7m²
Foundation Bolts M30 × 1100 mm
Support Structure 1200 mm Steel Channel Base

 

Overall and mounting dimensions(mm)


LW36-126T-(W)3150-40-dimension

 

Main Components

Component Description
Primary Terminal Aluminum Alloy
Bushing High-Strength Porcelain
Current Transformer Built-in Bushing CT
Interrupter Horizontal SF₆ Dead Tank Chamber
Operating Cabinet CT26 Spring Mechanism with Secondary Terminal Block
Support Frame Hot-Dip Galvanized Steel
Ground Terminal One Ground Pad per Support
Heater Optional Depending on Ambient Temperature

 

Typical Applications


The LW36-126T SF6 Dead Tank Circuit Breaker is designed for reliable operation in various high-voltage transmission and substation applications, including:

  • 72.5kV and 126kV transmission substations
  • Utility transmission and distribution networks
  • Transformer feeder protection systems
  • Bus coupler applications
  • Capacitor bank switching systems
  • Industrial power substations
  • Renewable energy grid connection projects
  • Heavy industrial power facilities
  • Coastal areas and high-pollution environments

With its compact dead tank structure, advanced SF6 switching technology, and reliable outdoor performance, the LW36-126T provides an effective solution for modern power grid protection and switching requirements.

 

Why Choose the LW36-126T SF6 Dead Tank Circuit Breaker?


The LW36-126T combines advanced design features and reliable performance for high-voltage power applications:

  • Integrated dead tank circuit breaker with built-in current transformer (CT)
  • Advanced SF₆ insulation and arc-extinguishing technology
  • Rated voltage up to 126kV
  • Rated current up to 3150A
  • Short-circuit breaking capacity up to 40kA
  • High-quality IKO, INA, and SKF bearings for enhanced mechanical reliability
  • Mechanical endurance of up to 10,000 operating cycles
  • Stainless steel control cabinet and hot-dip galvanized steel structure
  • Excellent corrosion resistance for demanding outdoor conditions
  • Online SF₆ gas density monitoring system
  • Rapid energy storage time within 15 seconds
  • Simplified installation and reduced maintenance requirements
  • Suitable for transmission substations, utility networks, capacitor banks, and transformer switching applications

 

Customization Services


Dxellence provides comprehensive customization solutions to support different utility, EPC, and industrial power project requirements.

Available customization options include:

  • Various rated current configurations
  • Anti-pollution (W) design options
  • Customized control voltage solutions
  • Auxiliary contact configurations
  • Current transformer ratios and accuracy classes
  • OEM and private label manufacturing services
  • Factory Acceptance Testing (FAT)
  • Complete technical documentation and engineering support

Our engineering team can customize the LW36-126T SF6 Dead Tank Circuit Breaker according to IEC, ANSI, and project-specific technical requirements, ensuring reliable integration into global high-voltage transmission and power distribution projects.

Agent
1
Request Quotation

    Get in touch
    To assign a dedicated Power Quality Engineer for your project drawing and fast quotation, please verify your WhatsApp Number/Email:
    Scroll to Top